for hotel pellet hot water boiler

Factors boiler flue gas dew point: boiler flue gas water vapor begins to condense is called the dew point temperature, dew point level on many factors. The water vapor content of the flue gas water vapor partial pressure multi i.e. high, the dew point. However, the partial pressure of water vapor dew point thermodynamic decision is low, e.g., oil-fired boiler in general, the flue gas water vapor partial pressure of about 0.08 to 0.14 atmospheres absolute, and the corresponding thermodynamic dew point of 41 ~ 52 ℃.

Boiler plant equipment as three major important energy conversion device, fuel chemical energy into heat energy, and the pot was heated using thermal energy to become hot water having a sufficient quantity and a mass (steam temperature, steam pressure) steam turbine for use. The Anyang City, the power company to my company to buy a split 2 tons of steam condensing gas steam boiler for supplying electricity demand. The WNS series split condensing boilers using advanced technology designed to greatly improve the thermal efficiency of the boiler, up to about 96%.

Furnace pressure Gaoyao what measures the phenomenon 1, high pressure boiler furnace alarm. 2, DCS furnace pressure is abnormally high. 3, the chamber is not tight at the gray smoke, Mars. 4, the furnace pressure is higher than 1960kPa, MFT operation. Reason 1, induced draft fan vanes, baffles false import and export clearance. 2, the milling system is not working properly. 3, the local detonation combustion instability. 4, furnace pressure automatic control failure. 5, the flue baffle erroneous off, the flue gas flow decreases through. 6, the boiler heating surface squib. 7, the induced draft fan trip, the corresponding side of the blower is not tripping. 8, a trip desulfurization booster fan. 9, the automatic air supply failure, sudden increase in the degree of opening. 10, out of focus. Now normal furnace pressure adjustment process 1, such as furnace pressure value is not reached the MFT. 2, the automatic control furnace pressure failure, immediately cut automatic and manual adjustment, the adjustment process to guard against the fan surge. 3, the system for wind smoke flap check recovery. 4, Fan trip, corresponding to the non-tripping side fan, the blower immediately outage. 5, on the other causes a high furnace pressure, furnace pressure should be quickly adjusted properly.

Fourth, the technical boiler manufacturers to provide maintenance support case.

Identify selling gas condensing boiler quality, we should also understand the situation better after-sale technical support for producers. Equipment during use, it may be some failures because of uncontrollable factors such as the operation or use of the environment, good quality gas condensing boiler businesses can provide regular on-site technical training and technical testing to ensure the boiler operation.