steam generators electric boiler for pharmaceutical

Steam boiler heat loss is what causes? Steam boiler heat loss caused to the user a lot of burden, whether it is hot steam boiler what is causing the loss of it? To analyze together with you today. Specific causes heat loss of the steam boiler at several: 1: heat loss of exhaust energy: smoke exhaust gas boiler comprises means losses are not completely absorbed by the steam heat loss. How caused? Short distance high temperature flue gas fan suction force is too high, the high temperature flue gas immediately excluded from the boiler; a small heating area, high temperature flue gas boiler can not be sufficiently absorbed. 2: the fuel gas does not completely heat loss: the combustible gas discharged from the flue gas generated in a boiler, the fuel in the combustible gas or gaseous fuel combustion process itself does not contain all of the incomplete combustion releases heat losses arising. As the incomplete combustion of carbon monoxide and carbon dioxide containing off-gas produced by combustion compared to the complete, only a quarter of the amount of heat released. 3: Solid incomplete combustion heat loss: refers to the solid fuel combustion process as a fuel grate down the drain does not release the heat of the flammable substance and ash contained in the combustion of the fuel can not completely burned released heat loss caused. 4: Loss steam boiler Grate: refers to the internal heat loss of the absorbent. 5: high temperature heat loss: Indicates high water temperature and hot water temperature, heat loss. 6: heat losses within the steam generator tube due to furring bilingual.

Electric heating steam boiler can be placed directly in the workshop steam from a steam boiler which is heated electrically to a point, then steam plant, that is, becomes condensate. Particularly to night non-continuous steam plant, each time before using the steam that is discharged will require large amounts of condensate, this time, that means the waste of energy. Then, it is on will be more in the management of personnel, need to be arranged over the holder Boilermakers were on duty, this way, that will increase the cost of the manual. To highlight the advantages of the now traditional electric heating steam boiler steam boiler, the first point is concerned, it is more to save energy, because eliminate the loss on the transport network, which is the way of saving energy will supply steam than conventional 30 -50%, so in terms of the case, which is able to meet the requirements of sustainable development. It is to pay attention to will be relatively simple in management, on the steam generator electric heating steam boiler that is, would not fall within the scope of the pressure on the boiler, this time, that can be placed directly on the shop inside, not We need to use a separate boiler room building. When needed direct steam plant workers on the steam boiler is heated by electricity will also be turned on, and the factory will be more beautiful.

Electric steam boiler electric steam boiler Notes Notes 1. Follow all warnings and instructions on the machine brands. 2. In order to prevent a negative pressure in the boiler, after sewage, before the next boiler operation, please do not close the drain valve. 3. In order to ensure the normal operation of the steam generator and security, should always observe the operation of the boiler pressure boiler, heating the water level and the situation is normal. When the steam generator failure, should immediately stop check, troubleshooting before the restart. 4. When the boiler stops longer running time, cut off the power while the boiler, the water inside the pipe exhausted to prevent frost damage, rusting. The machine usually is not used, power off, the control box is opened, check all the electrical device terminals fasteners, looseness should be sturdy, to prevent bad burning ignition wires have electrical device. 6. The electronic control box may not be water or steam and flammable gas, electric cabinet must shut the door in the boiler running. Never electrical control member any liquid or water flowing into the system, such as motors, electric control box. Cause gas boiler burner ignition misfire rod causes gas boiler burner ignition misfire bar: 1, the ignition bar gap interposed carbon residue with oil. 2, ignition rods fragmentation. moist. Leakage. 3, the distance between the ignition does not stick, too long or short. 4, ignition rods Insulation damage, short to ground. 5, ignition cable and transformer failure: cable, connector damage caused by a short circuit during ignition; transformer break or other fault occurs. Gas Burner fails, the action bar ignition misfire following five: Clear, renewal, adjust the distance, change and switching transformer.

In the transformation process, side by rapid technical engineers FGR advanced combustion technologies, the use of flue gas recirculation and the outer loop is provided, withdrawing part of flue mixed with the combustion air, and then into the furnace through a burner, not directly part in the combustion, by reducing the effect of the combustion flame temperature to reduce the temperature and oxygen concentration, to achieve the purpose of reducing NOx generation. For now, for a large volume of gas boilers, low compared to the overall transformation of nitrogen to replace the boiler equipment will save a lot of costs. Fast boiler has a boiler in research and technology low nitrogen aspects of considerable industry experience, successful completion of the reconstruction project Dingzhou low nitrogen Erie boiler, significant cost savings for businesses.