crude oil boiler main parts

palm biomass crude boiler main parts to produce electricity for palm oil mill

PRODUCT INTRODUCTION fuel gas-fired crude boiler main parts fuel gas-fired boilers and coal-fired steam boiler is not the same, gasoline and diesel and gas-fired burner must be poured into the fuel to the boiler furnace using a combustion chamber rather than grate facilities. Since the fuel gas-fired boiler is not easy to cause the fly ash lit, so no oil or gas boiler slag removal equipment. If mixed with air or exterminate within a certain range, it is introduced into the furnace petrochemical and gas easily the explosive. Thus, any gasoline and diesel and gas-fired boilers must be selected and automatic combustion control system. Compact boiler fuel gas, and the small boiler exhaust, drainage, control and auxiliary equipment installed at the distribution panel, and produce large and small boiler assembly. Fuel gas-fired boiler safety valve installation key point describes the installation of fuel gas-fired boiler safety valve sure to carry out in accordance with reasonable installation process, to prevent wrong and lead to risk. Fuel gas-fired boiler safety valve installation should pay attention to what matters? The following is a brief description: 1 oil-fired boiler safety valve having a lever bar to avoid self-weight and the mobile device guide body defining deviant lever, the spring valve lift handle and avoid the need for screw adjustment means random twist. 2. Rated evaporation than 0.5t / h gas boiler safety valve should be arranged at least 2, Rated evaporation gas boiler should be equal to or less than 0.5t / h, fitted with at least one safety valve. Separable economizer outlet and a steam superheater outlet valve should be installed. Sectional area of ​​the connecting pipe between the boiler safety valve 3. Fuel gas boiler can not be lower than the imported cross-sectional area of ​​the valve. If several valve mounted on each stub is directly coupled to the drum, the passage sectional area of ​​the stub is less than 1.25 times not all of the area of ​​the exhaust valve. 4. Oil and gas boiler safety valve should be mounted vertically in the height of the boiler drum and the header. Can not be mounted between the valve and the steam outlet conduit and the valve drum or header. 5. For rated steam pressure less than or equal to 3.82MPa boiler safety valve throat diameter of not less than 25 mm; the rated steam pressure is greater than 3.82MPa boiler safety valve throat diameter of not less than 20 mm. 6. Fuel gas boiler safety valve should normally be established an exhaust pipe, the exhaust pipe should be directly connected security grounds, and there is sufficient cross sectional area to ensure the smooth flow of the exhaust gas. The bottom of the valve should be equipped with an exhaust pipe connected to the drain of a safe place. Valve must not be installed in the exhaust pipe or drain pipe.

Structural characteristics and rational utilization of the power of the furnace structure characteristic electric crude boiler main parts hydraulic computing There are two methods for electrical boiler furnace: a designing new electric boiler, first by combustion requirements, according to the selected grate area of ​​the heat strength and the furnace volume heat intensity, determined baked and a preliminary discharge area is determined that the furnace volume, structure and size. Two boilers according to preliminary estimation method is recommended to determine the area of ​​the grate and furnace volume. Now Yaoan claim preliminary heat radiation heating surface arranged in the furnace, and the furnace structure is arranged drawn sketch, thereby performing the furnace structure characteristic calculation. When checking the conventional electric boiler furnace, if its structure is known, the furnace must be characteristic calculation means. Electric boiler furnace structure characteristic calculation means provide the necessary data for the furnace heat. After the furnace when the heat transfer calculation, checking furnace exit gas temperature is unreasonable, the institutions respond to the furnace and the radiation heating surface is arranged to be modified, and then calculated. The surrounding electric boiler furnace volume: Wall roof and around the center line of the plane (if the waterwall tubes covered with a refractory coating live bricks, where the surface is not Wall for Xianghuo arranged to the furnace wall surface of the wall. outlet chimney at the top of a row of tubes centerline) and a bottom surface of the plane. Unavoidable presence of various types of hydraulic oil flowing through the hydraulic valve when the pressure drop and flow loss, energy loss in this portion of the large proportion in the total energy loss. Therefore, a reasonable selection hydraulic, a pressure adjusting valve is also an important aspect of power loss reduction. Flow valve flow rate adjustment system according to the range of the minimum select and ensure stable flow can meet the requirements, the pressure in the pressure valve satisfied hydraulic equipment work properly, try to get a lower pressure. A reasonable choice of hydraulic oil. When the oil flow in the pipeline, will exhibit a viscosity, while too high viscosity, will have a greater internal friction, resulting in heating oil, while increasing the fluid flow resistance. When the viscosity is too low, easily lead to leakage, reducing the volumetric efficiency of the system, therefore, generally choose suitable viscosity and good viscosity-temperature characteristics of the oil. Further, when the oil flow in the pipeline, there is also along the local pressure loss and the pressure loss, so the design of the pipe line as short as possible, while reducing elbow.

Burns Hospital Affiliated Hospital of Shanxi Linfen Linfen Steel is attending a hospital burns burns and other diseases. Hot water crude boiler main parts is essential hospital equipment heat, hot water output can provide disinfection of medical instruments and ward heating demand. With constantly improving our environmental policy, boiler correspondingly introduced more sophisticated Use. Linfen hospital burns to respond positively to the national environmental policy, decided to introduce an environmentally friendly low nitrogen gas hot water boiler. Taking into account the special circumstances of the hospital, the boiler should also have the use of safe, clean overall characteristics. Based on the above considerations, finalize the Linfen hospital with burns boiler party cooperation fast, fast is provided by one side of a gas condensing pressure hot water boiler (CWNS2.1-95 / 70-Y.Q).