steam boiler 300kg steam generator wood pellet

Beiqi Panthers in the car to communicate with the company, expressed full confidence in our company, cooperation is very smooth. Since the boiler departure two years, our technical staff has been concerned about the relevant boiler operation through remote monitoring system to provide strong and stable technical support services for the Beijing auto Panthers. --customer feedback

Why can steam boiler 300kg steam generator wood pellets exemption? You can exempt steam boilers What are the benefits? According to the "Steam Boiler Safety Technology Supervisory Regulations" provides water capacity less than 30L in the boiler does not belong to the scope of the surveillance. According to the "Steam Boiler Safety Technology Supervisory Regulations" provides water capacity less than 30L in the boiler does not belong to the scope of the surveillance. The steam generator water capacity of only 26L, like installing a home water heater as safe. So, Yinxing boiler steam boiler belongs to the exemption. You can avoid the security of small steam boiler What are the benefits? 1, you can not build a separate boiler room, can be placed in the basement, roof and other places 2, do not have a full-time duty Boilermakers (conventional boiler requires certified fireman) 3, eliminating the need for a year dealing with government departments, more peace of mind gas gas steam generators have any advantages over electric heating steam generator? Electrically heated steam generator is a small steam generating device. But steam production of electric heating steam generator is very small, and relatively low overall efficiency, the steam pressure generated steam temperature is relatively low, only suitable for use in the canteen steamed rice and the like occasions. Also much higher operating costs than on Yinxing gas steam boiler. The steam generator What are the advantages over conventional steam boiler? Steam boiler, is lower than conventional gas steam boiler safety running costs, fast start, no registration and annual inspection. Gas boilers suitable for use in what place? It can be used in hotels, factories, hospitals and other occasions. The hotel can be used as a steam boiler steam laundry places, canteens and other uses. As plant steam for a steam boiler may be used in the process. Steam boiler can be used as a hospital to disinfect hospital use. Free acceptance steam generator characteristics: 1, automatic water features: During operation, the pump automatically add make-up water, so the water level inside the work holder itself, it provides continuous high pressure steam to the external device. Without special care. 2, the triple pressure automatic protection to ensure safe and reliable devices: a weight Protection: when the body of the steam pressure reaches the upper limit of the pressure set by the controller can automatically cut off the heating power, when the body of reduced vapor pressure to the lower limit of the set , it can be automatically connected to the heating power, in order to ensure a substantially constant steam output pressure. Double Protection: the accidental causes the body to use the steam pressure exceeds the pressure limit set by the controller, the relief pressure automatically cut off the heating power controller. Triple protection: When the pressure in the pressure on the body due to an unexpected reason than the set limit safety valve, safety valve can be effective and timely release, in order to protect the safety of equipment and operating personnel. 3, dry automatic protection: accidental causes the water level falls under the level of the body, can be automatically cut off the heating power to ensure that the heating element will not be damaged due to the dry water. 4, is as a multi-chamber structure, two transition chamber by steam treatment, saturation is greatly improved, and a cool air discharging means, to ensure the quality of the steam, the steam quality requirements for higher user ideal. 5, the housing 304 drawing steel sheet, attractive and durable. 6, the control components used Schneider Electric or Siemens programmable and touch screen, reliable and durable. 7, plus turbo pump high-pressure pump, high pressure, low-power, reliable and durable. 8, a pressure and a water level automatic alarm device, a failure to timely processing.

The method is properly installed steam boiler 300kg steam generator wood pellet when we sent you receive your steam boiler, you must be very happy, but at the same time, certainly some questions. Fuel gas boiler is not only fuel but also refers to the gas boiler. Previously no such dual-fuel boiler, burner because either fuel or gas, no dual fuel burners. With the rapid development of the world energy equipment, some European countries begin production and sales of fuel gas burner, dual fuel burner and boiler combination of organic birth of a new breed of boiler - fuel gas-fired boiler. Electric heating boiler and the boiler is mainly composed of electric control box and control system. Its characteristics are environmentally friendly, clean, no pollution, no noise, automatic, with limited energy and reduce prices significantly, as a new boiler electric heating boiler equipment increasingly being recognized. Electric heating the core member is electrically heated boiler, directly determines the life of the boiler, to select a non-metallic electrical heating tube (such as a ceramic heating pipe), because it is resistant to the load, a long life, and a water separation structure, the boiler Wing no leakage. How to install steam boilers correct? Do not worry. We Eastern Machinery not only produce high quality boiler, but also have high-quality after-sales service. We teach you how to properly install. First, in order to investigate the installation environment, boiler room layout should prior approval of the local quality and technical monitoring section, and install a separate boiler room installed in ventilation, cooling, easy to operate and convenient place to smoke. Not near flammable or explosive material, electrical installation technicians should be installed in accordance with the requirements of the relevant national standards, and N and L error can not be connected. When using gas as fuel, explosion-proof electrical equipment should be installed, from the switchboard should 6m above the pan. Secondly, the ground electric steam boilers relation to the safe use of the boiler. For this reason, reliable ground should be installed, should be stored in the vicinity of the ground, the depth should be greater than or equal to 1.5 m, the ground should be sintered at a cable joint ground pile head. In order to prevent corrosion and moisture, the connection joint should preferably 100mm above the ground. Boiler chimney to be discharged should be extended to the outside, the outlet should be 1.5 to 2 meters higher than the boiler. After installation, the local special equipment maintenance department should be declared. The relevant part of the experience received consent to use, and has made use of certificates boiler before use. Volume is less than the vapor pressure of less than 0.1L or 30L steam generator belonging to the National Inspection-free range, that is, without the use of a certificate issued by the boiler can be used. Follow the steps editorial suggestions, I believe you will be able to successfully install a steam boiler!

2. Steam boilers in palm oil factory

Steam boilers produce superheated steam, used to generate electricity through turbine generators. The lower pressure steam from the turbine is used for heating purposes throughout the factory.