taishan coal fired steam boiler szl

SZL series boiler is a biomass boiler widely sold at home and abroad. CBM provides a 10 ton SZL taishan coal fired steam boiler szl for a company in Tanzania. The SZL series boiler adopts advanced technologies and has many advantages. The 10 ton szl biomass steam boiler could burn biomass fuel, bituminous coal and others.

Gas and coal-fired taishan coal fired steam boiler szl steam boiler at any time there is any good compared to the country more and more attention to environmental protection, coal-fired steam boiler has been a great blow, and relatively gas steam boiler by many users of all ages, in recent years the country also vigorously promote the use of gas-fired boiler, then what are the benefits of gas compared with coal-fired steam boiler steam boiler it? And today we work together to explore. Gas-fired steam boilers and coal-fired steam boilers on the market each accounted for half of the country, showing potential rival, but in the long run, gas steam boiler will obviously be the only dominant market. Do not believe, look! 1. Purchase costs: gas boiler is evident in the technical and auxiliary facilities are far ahead of coal-fired boilers, and it is equipped with a special gas burner. 1 steam boiler tonnage, for example, than the price of coal-fired boiler gas boiler on high about 30%. 2. Construction costs: The costs mainly from the boiler room. Because the corresponding auxiliary equipment more coal-fired steam boilers, so the boiler room construction funds have more. The gas boiler auxiliary facilities require little or automatic control and operation, and automatic alarm and automatic protection, not only save building costs, but also safe and reliable; Also connected to the gas pipeline, the burner will automatically supply gas can effectively save costs staff. The coal-fired boilers because of the need of coal on the program, so it needs some staff payroll. 3. Fuel cost: around this by looking at the actual specific fuel price can be clearly seen. The fact is that the amount of gas than burning coal per hour to be much more. 4. environmental costs: in the need to protect the environment, review the current coal-fired boiler more strict. The gas steam boiler due to the operation of the economy, environmental protection and energy saving, as well as government policy to encourage more and more widely used.

Fangkuai Group adopts the concept of “moulding character and creating high-quality products”, and continues to research and continuously improve the technological content of products to get closer to users. With the mission of “creating convenient and fast boiler high-quality products for users”, it uses remote monitoring, APP, and active return visits. And other channels to provide users with convenient and efficient services; with the core values of "professionalism, lean work" as the core value, established an effective enterprise management system, adopted ISO9001 quality management system, OHSA18001 occupational health and safety management system and ISO14001 environmental management System certification; and cultivated a large number of high-quality employees with norms of behavior, professionalism, and continuous commitment to provide customers with more convenient and efficient services.

Shutdown four tons of gas boiler taishan coal fired steam boiler szl shutdown and maintenance of fire into pressure shutdown, normal shutdown, emergency shutdown. A pressure fire fire shutdown shutdown pressure applied to temporarily stop the supply of steam, the boiler is shutdown pressure hot standby state. 1, before the pressure reduction appropriately to fire the boiler load, and according to the length of the seam thicker shutdown time, (up to 200mm) to accelerate the speed of the grate, the grate is stopped when rotated about 1.5 meters from the coal seam to the shutter. 2, stop blowers, blower suitably adjusted flap subsections, relying on a lean-burn natural ventilation is maintained. 3, the sewage, to allow the water level in the boiler water level. 4, Yang fire regularly, to prevent rotation of the furnace grate extinguish the fire bed. Young fire first before sewage water, then rinse water level gauge. II. Normal shutdown Normal shutdown for heating period ends, boiler pour fire into the buck repair or maintenance. 1, make a record before shutdown problems in operation, so that after the shutdown process. 2, the coal bucket coal memory runs out, the amount of toner to reduce the wind. 3. Stop the blower, draft fan stop and then the opened door grate ash. 4, after the steam supply is stopped out, the boiler to the boiler water to maintain a high level. 5, close the main steam valve, if the pressure rises to open the air exhaust valve suitable pressure relief. 6, stop the water supply to the boiler and economizer attention to monitoring changes in water temperature, open return pipe if necessary. 7, 4 to 6 hours after the furnace fire bed down exhausted, continued rotation of the cooling grate. Throughout the boiler throttle, the door should be kept closed. Allowed to naturally cool. 8, appropriate to open the pump, the boiler water and sewage. When the pressure drops to zero, open the air valve. 9, when the boiler water temperature is below 70 ℃, boiler water can be exhausted. Shutdown is complete. 10, less than 24 hours during shutdown. Avoid Shutdown cooling process, step-down too fast. Third, emergency shutdown emergency shutdown applies to the boiler accident, g combustion equipment damage, furnace or boiler structure collapsed wall is red-hot, a serious threat to the safe operation of the boiler when; h boiler pressure parts found serious distortion, leakage. when i found flue gas explosion or secondary combustion, boiler and seriously endanger the safety of operating personnel;; when endanger the safety of operation.. the safe operation of the boiler j endanger other unusual circumstances when. 2, the emergency shutdown procedures to immediately stop a blowing coal and reduce the wind; B rotates quickly grate, the pour slag pit coal or sand, wet ash coal burning fire to extinguish. , but not to the firebox water;. c boiler air valve, the relief valve opens quickly exhaust the steam pressure is reduced;. d after the fire goes out, stopping fan, opening the ash door and door, promote air circulation accelerated cooling; 3, emergency shutdown Notes a. when an accident and emergency shutdown due to lack of water, boiler feed water is strictly prohibited to, and shall not be such as to open the air valve or exhaust valve work on preventing boiler from sudden changes in temperature or pressure to expand accidents;. b when filled with water due to an accident and emergency shutdown, should immediately stop the water supply, reduce combustion, open the drain valve and drain, due to lower the water level, while opening the main steam pipe, the sub-cylinder and steam traps mother tube, water and prevent steam pipe with a large number of water hammer occurs. c. emergency shutdown operation to ensure the safety of the main event of an accident to calmly deal with, timely reporting, and make relevant records in the "log table boiler." d. Whether shutdown any case, we must maintain timely contact with steam departments.