electric power electric heating hot water boiler

1 electric steam boiler maintenance, maintenance when the boiler must be cut off and must relief. 2, the burner every two months to be removed from the boiler, carefully remove foreign bodies such as dust and soot. Photocell light-receiving surface wipe once a month, fuel filter should always be kept clean and filtering capabilities; carefully clean the filter in the pump, do not break the seal. Oil-burner not idle, so as not to damage the pump. 3, the water level gauge should always be kept clean, rinse the purge valve is opened, the water level in order to ensure a clear day. 4, pulling the safety valve once a day, to prevent rusting failure. 5, the boiler stops longer running time, cut off the power, and do maintenance work: (1), dry maintenance, shutdown after the release came out water, dirt clean the furnace, slow fire the pot with a burner after drying (burn time not too long, to avoid damage to the boiler), then drain all of the gas boiler, all pipe valve closed, checked every three months. (2), wet maintenance for a period not exceeding one month shutdown of the boiler, furnace shutdown after water release, discharge and clean fill with water, cut off the power, close the valve.

Steam boiler which automatically displays the instrument will encounter problems in accordance with the steam boiler fuel can be divided into electric steam boiler, steam boiler fuel, gas steam boiler using the water level; in accordance with the constitution can be divided into vertical steam boilers, horizontal steam boiler, small steam boiler mostly single, double the return of the vertical structure, large steam boilers and more horizontal structure of three return. There lowland water or a display apparatus using the automatic water level when the water level in steam boiler water level is only a low level of installed devices, and even water pipes are too small; the water level or a Low level using the instrument, when the steam boiler is automatically displayed only one water; a water drain device, drain cocks no ground; on a drum water level is effective, other water damage; plug screwed on the fixed level; on tap water gauge leak, leaking; water false water level on the display unit; the drum water level in the two water gauge level of inconsistency; water is often broken glass; water gauge glass without guard; a water gauge glass plate not shown in the red line indicating the water level; water gauge glass plate is dirty, the water level observation is unclear. Steam boiler water level glass observation level of inconsistency and the main reason is unclear steam boiler for long periods of time rinse in running water, a daily maintenance is not carried out, resulting in water cock rust, gas, water and even the block, or insufficient packing or aging deterioration. False water level phenomenon, in addition to gas, water or even the cock pipe is blocked, but also could be vapor, the water pipe connected to the water level due to misalignment connected; steam, water tap handle installed the wrong position resulting cock closed, since there poor water quality, the water level in the boiler and false priming. Water gauge glass is broken mainly steam, water faucet centerline not aligned, the presence of glass bending stress; long glass without expansion gap; water gauge is being cold draft at window glass, and glass pipe quality was poor. During the operation of the boiler, the water level was found is not clear, to shutdown immediately ultra-high water level, timely detection of problems.

What is its auxiliary boiler feedwater oxygen has several categories? Boiler, I believe we are not unfamiliar with and understand it, if you have been concerned about the site and read the relevant article and master the relevant knowledge and content words, so below, it may be in front of the existing foundation, to continue the products of study and work, so that we can make progress in their learning and development road, and at the same time, you can also reach the intended target as quickly as possible. 1. ship boilers and boiler land, they are the same? Can GM? Marine boiler, which is used to generate steam, or fuel for heating domestic water, and may also be in the kitchen in the ship. However, it is compared with a land boiler, there is a big difference, such as shape and size. So, they are not identical, nor is it universal. 2. auxiliary boilers, there are a few main categories? Auxiliary boilers, which can be divided into six categories, the specific terms, it is the coal slag or counseling classes, containers, water treatment class, class fans, smoke and dust classes and appliances category. Wherein an expansion device containers, and other such sub-cylinder, the fan type blower and is mainly induced draft fan. The appliances, mainly for electric and control these two aspects.

Our company attaches great importance to the quality of wine, winemaking process steam requirements provided very strict, party fast boiler provides fully meet our needs, give us a brewery to provide strong support. --customer feedback