biogas fired steam boiler palm oil making

Henan gas treatment condensing boiler operation in the secondary combustion Accident Henan condensing gas boiler, deposited in the rear of the boiler flue gas condensing Henan combustibles (soot, carbon black) re-ignition combustion phenomenon called secondary combustion, also known as Henan condensing gas boiler flue tail and then burned. It will backpass severe, air preheater, induced draft fan and other equipment economizer even destroyed. 1. Henan condensing gas boiler secondary combustion phenomenon (1) a sharp rise in exhaust gas temperature, chimney to take smoke, fire or even smoke. (2) changes drastically furnace pressure, positive pressure occurs. (3) severe flue enclosure dark red. (4) when there is an air preheater, a sharp rise in the temperature of the hot air, pressure instability. (5) blast doors sometimes the tail action. Cause 2.Henan condensing gas boiler secondary combustion (1) poor atomization burner, oil, gas and incomplete combustion into the rear of the boiler. (2) combustion improperly adjusted, with insufficient wind or with the wind unreasonable. (3) Henan condensing gas boiler startup, shutdown during low furnace temperature, the unburned fuel in the furnace. (4) When shutdown or boiler fire, air gun valve is not closed. (5) the combustion chamber negative pressure is too large, too late to make the gas burn it into the rear of the boiler. (6) Long-term non-stop cleaning backpass furnace, accumulating a certain amount of soot or carbon black. (7) through the air preheater flue or leakage. 3. The gas processing condensed Henan secondary combustion boiler (1) should immediately stop the gas, stop the wind, shutdown. (2) closing the flue, and a baffle duct around the door opening, is prohibited to start sending, induced draft fan. (3) immediately extinguishing device into steam, carbon dioxide or other fire extinguishing means, (4) Strengthening Henan condensing gas boiler feed water and turn on the water, open the valve or economizer recirculation tube to protect the economizer is not burning. (5) When the exhaust gas temperature close to the temperature of the injected steam, or less than 150 deg.] C over 1h and stable openable inspection hole inspection, after checking element determines an ignition source, before the fan starts ventilation and cooling. (6) when the temperature drops below the flue 50 ℃, check before entering the flue tail heating surface, and should completely remove the flue soot. If not burning, can be re-started ignition; if burning, should be replaced, repaired burning member.

Gas oil furnace fuel additive effect and the boiler room Notes: Gas oil furnace, oil furnace that is both in one, and, still in the boiler in this category, so, based on this, the following will continue be familiar with and understand the boiler, because it is the product website and keywords. Moreover, we can also derive some new knowledge, in turn, make progress and development in their learning path. 1. Gas oil furnace, which is a fuel additive, then what good? Gas conducting oil furnace, in which fuel additives, it is possible to optimize the fuel, and reducing soot and improving thermal efficiency. However, it should be noted that, in addition amount to control the well, in moderation, too much or too little, will always have problems, thereby, affecting the normal combustion of the fuel. 2. Gas-fired biofired steam boiler palm oil making and gas oil furnace, boiler room can both jointly built it? Gas-fired steam boiler and gas oil furnace, two boiler room, is jointly built, and that is no problem. However, it should be carried out in accordance with the steam boiler room equipment specifications and oil furnace room design specifications, avoid mistakes, and at the same time, to make the two boilers, a good use of effects.

Biomass boiler case:

The animal feed plant has a seasonal operation, but a relatively consistent load profile. The peak load is for 850 kg/hour of saturated steam at 8 barg (~650 kW see Figure 3). There is a much smaller load required for longer periods for miscellaneous process steam. The load is currently supplied by a very old light fuel oil (LFO) boiler. The load profile here facilitates an almost complete switch from LFO to biomass. 96% of the steam requirement would be covered by a 650kW biomass boiler. A small oil boiler, or built-in oil burner in the biomass steam boiler would be required to meet the smaller steam loads which would not be met efficiently by the biomass boiler. A straight-forward moving grate boiler with fire-tube heat exchangers can be used. The range of suppliers of biomass steam boiler equipment is limited below 1MW thermal as economies of scale are diminished below this level – a 650 kW boiler costs almost the same as a 1MW boiler.

Directly under the Central Government Offices Administration (referred to as the straight Authority) is the CPC Central Committee and subordinate units, are responsible for the CPC Central Committee and services for the organs and services, an important function of serving the people. Central Government institutions funds, finance, public service vehicles, the state-owned assets and real estate management, service management is responsible for the specified life of the party and state leaders as well as services related objects.